A VIT study printed two auxetic lattice geometries on the same Creality LD-002R in the same resin and got a fourfold difference in peak load from cell shape alone. Here is what the data supports and where it stops.
If you design lattices, the usual advice is to pick a cell geometry, then tune relative density and wall thickness until the part is stiff enough. A study from Vellore Institute of Technology in Tamil Nadu, published as an Article in Press in Scientific Reports, puts a number on the first variable in that list. Two lattice geometries, one resin, one printer, one test rig: swapping a re-entrant hexagon for a star-triangular cell raised peak load roughly fourfold and energy absorption roughly threefold.
That is a big effect from a change you can make in the CAD tree in ten minutes.
What was actually held constant
The comparison is useful precisely because almost nothing else moved. Both designs were modelled in Autodesk Fusion 360 from unit cells 10 mm tall with 1 mm walls and members angled at 30 degrees, then patterned into blocks 30 mm high and 20 mm deep. Both were printed in Anycubic Standard Photopolymer Resin on a Creality LD-002R, a budget LCD resin machine, sliced in CHITUBOX at 0.05 mm layers with a 6 second exposure per layer. Both were washed in isopropyl alcohol and UV post-cured. Four specimens of each design went to the same Tinius Olsen H10KL with a 10 kN load cell, compressed at 2 mm/min to 40 percent crush following the ASTM D695 loading procedure.
The authors are open that the blocks did not match the solid sample dimensions ASTM assumes, so they borrowed the standard's loading setup rather than its geometry. A fair compromise, but keep it in mind when reading the absolute numbers.
The results, including the awkward one
The best star-triangular block, NB1, hit 3.8 MPa peak stress and about 2,700 N of force, then dropped sharply after the peak. NB2 followed at 3.1 MPa and 2,200 N with a more gradual fall after the peak. The best hexagon, NA3, reached 0.89 MPa and 660 N. Full table from the paper:
| Specimen | Peak stress (MPa) | Peak force (N) |
|---|---|---|
| NA1 hexagon | 0.45 | 280 |
| NA2 hexagon | 0.64 | 400 |
| NA3 hexagon | 0.89 | 660 |
| NA4 hexagon | 0.86 | 650 |
| NB1 star-triangular | 3.8 | 2,700 |
| NB2 star-triangular | 3.1 | 2,200 |
| NB3 star-triangular | 0.6 | 500 |
| NB4 star-triangular | 1.2 | 700 |
Now the awkward part. NB3, a star specimen, came in at 0.6 MPa, below three of the four hexagons. Peak stress across the star group spanned 0.6 to 3.8 MPa. With four specimens per design the team could not compute standard deviations or error bars, and they say so plainly. Their call is that the average effect is large enough to be worth reporting, not that any individual star lattice will beat any individual hexagon.
The mechanism they propose is more connecting nodes and better load paths in the star cell. The Abaqus finite element model agreed, showing stress concentrating at re-entrant joints and the lattice failing layer by layer as walls folded inward. The model was first validated against a published 2021 ABS lattice study, landing within 2.91 percent on stress and 2.63 percent on displacement, which is the sturdiest part of the whole paper.
What to take into your own designs
Geometry is not a footnote in resin lattices. If your part is load-bearing or impact-facing, change the cell shape before you start shaving wall thickness or adding material. The authors suggest re-entrant hexagons where you want even, progressive crushing: padding, insoles, ergonomic products, implant structures. They point at star-triangular cells where you want peak strength and impact resistance: sandwich panels, crash absorbers, protective gear.
Two cautions from someone who has watched people over-read lattice papers. First, this is one brittle standard resin on one printer. Anycubic standard resin is not tough, flexible or glass-filled, and layer adhesion in an LCD print is the failure path here, not the polymer's own strength. Second, the sample count means you should treat this as a strong prior and then run your own coupon. Print four of each shape in the resin you will actually use and crush them. It costs a roll of IPA and an afternoon.
What the study does establish is the thing that matters for a design decision: with everything else frozen, cell shape alone moved peak load by a factor of four. Most of us tune lattices as if only density mattered. It does not.
Comments (0)
No comments yet. Be the first!
Leave a Comment